BSM Instruments

Instruments & NABL Scope

What we calibrate, with the exact ranges and calibration capability from our scope of accreditation.

AccreditationNABL · ISO/IEC 17025:2017
Certificate No.NABLC0926PB04967
Valid until28 Jul 2030

Instruments

What we calibrate

Filter by discipline or search for your instrument.

Mechanical

Vernier & Digital Calipers

Vernier, dial and digital calipers up to 600 mm, plus depth and gear tooth verniers.

Mechanical

Micrometers

External, internal, depth, three-point and V-anvil micrometers.

Mechanical

Dial & Height Gauges

Plunger and lever dial gauges, bore gauges, thickness gauges and height gauges.

Mechanical

Pressure Gauges

Analog and digital pressure gauges and transducers up to 700 bar (on-site).

Mechanical

Weighing Balances

Electronic balances from 210 g to 100 kg, as per OIML R 76-1.

Electro-Technical

Multimeters & Clamp Meters

Digital multimeters and clamp meters: AC/DC voltage, current (up to 1000 A) and resistance.

Thermal

Thermo-Hygrometers

Temperature and humidity indicators, controllers and chambers (20–90 %RH).

Mechanical

Torque Wrenches & Testers

Click-type, dial and digital torque wrenches, screwdrivers and torque testers.

Scope of accreditation

Full NABL scope

Every accredited parameter, in our laboratory and at your site. CMC is the expanded uncertainty at about 95 % confidence (k = 2).

Instrument / quantityDisciplineRangeCMC (±)
AC Current @ 50 HzElectro-TechnicalAC (Measure)1 A to 10 A0.25 % to 0.27 %
AC Current @ 50 HzElectro-TechnicalAC (Measure)1 mA to 100 mA0.46 % to 0.17 %
AC Current @ 50 HzElectro-TechnicalAC (Measure)100 µA to 1000 µA1.35 % to 0.46 %
AC Current @ 50 HzElectro-TechnicalAC (Measure)100 mA to 1 A0.17 % to 0.25 %
AC Voltage @ 50 HzElectro-TechnicalAC (Measure)1 mV to 100 mV5.8 % to 0.13 %
AC Voltage @ 50 HzElectro-TechnicalAC (Measure)1 V to 750 V0.11 % to 0.12 %
AC Voltage @ 50 HzElectro-TechnicalAC (Measure)100 mV to 1 V0.13 % to 0.11 %
AC High Current @ 50 HzElectro-TechnicalAC (Source)100 A to 1000 A1.26 % to 1.33 %
DC CurrentElectro-TechnicalDC (Measure)1 A to 10 A0.2 % to 0.19 %
DC CurrentElectro-TechnicalDC (Measure)1 mA to 100 mA0.8 % to 0.08 %
DC CurrentElectro-TechnicalDC (Measure)10 µA to 1000 µA3 % to 0.8 %
DC CurrentElectro-TechnicalDC (Measure)100 mA to 1 A0.08 % to 0.2 %
DC Resistance - 2 WireElectro-TechnicalDC (Measure)1 kΩ to 1000 kΩ0.01 % to 0.08 %
DC Resistance - 2 WireElectro-TechnicalDC (Measure)1 MΩ to 100 MΩ0.08 % to 0.94 %
DC Resistance - 2 WireElectro-TechnicalDC (Measure)1 Ω to 1000 Ω0.5 % to 0.01 %
DC Resistance - 2 WireElectro-TechnicalDC (Measure)100 MΩ to 1 GΩ0.94 % to 2.3 %
DC VoltageElectro-TechnicalDC (Measure)1 mV to 100 mV0.75 % to 0.3 %
DC VoltageElectro-TechnicalDC (Measure)1 V to 1000 V1.5 % to 0.04 %
DC VoltageElectro-TechnicalDC (Measure)100 mV to 1 V0.3 % to 1.5 %
DC High CurrentElectro-TechnicalDC (Source)100 A to 1000 A1 %
DC Resistance - 2 WireElectro-TechnicalDC (Source)1 kΩ to 10 kΩ1.2 % to 1.54 %
DC Resistance - 2 WireElectro-TechnicalDC (Source)1 Ω to 1 kΩ1.85 % to 1.2 %
DC Resistance - 2 WireElectro-TechnicalDC (Source)10 kΩ to 100 kΩ1.54 %
DC Resistance - 2 WireElectro-TechnicalDC (Source)100 kΩ to 1000 kΩ1.54 % to 2.9 %
DC Resistance - 2 WireElectro-TechnicalDC (Source)2 MΩ4.1 %
DC Resistance - 2 WireElectro-TechnicalDC (Source)20 MΩ2.4 %
DC Resistance - 2 WireElectro-TechnicalDC (Source)200 MΩ3 %
DC Resistance - 4 WireElectro-TechnicalDC (Source)1 mΩ to 100 mΩ8.5 % to 2.2 %
DC Resistance - 4 WireElectro-TechnicalDC (Source)100 mΩ to 1 Ω2.2 % to 1.85 %
RTD (PT-100)Electro-TechnicalTemperature Simulation (Source)-200 °C to 600 °C0.87 °C
Thermocouple J TypeElectro-TechnicalTemperature Simulation (Source)50 °C to 750 °C0.92 °C
Thermocouple K TypeElectro-TechnicalTemperature Simulation (Source)50 °C to 1300 °C1.24 °C
Thermocouple R TypeElectro-TechnicalTemperature Simulation (Source)200 °C to 1700 °C1.62 °C
Thermocouple S TypeElectro-TechnicalTemperature Simulation (Source)200 °C to 1700 °C1.96 °C
TimeElectro-TechnicalTime & Frequency (Measure)1 s to 3600 s5.33 % to 2.44 %
FrequencyElectro-TechnicalTime & Frequency (Source)45 Hz to 999.9 Hz0.58 % to 0.3 %
Centrifuge - Non Contact TypeMechanicalAcceleration & Speed100 rpm to 2000 rpm1.8 %
Centrifuge - Non Contact TypeMechanicalAcceleration & Speed2000 rpm to 38000 rpm0.5 %
Tachometer, RPM Meter with Sensor - Contact TypeMechanicalAcceleration & Speed100 rpm to 3000 rpm1.8 %
Tachometer, RPM Meter with Sensor - Non Contact TypeMechanicalAcceleration & Speed100 rpm to 2000 rpm1.8 %
Showing 40 of 108 entries

Can't find your instrument?

Ask us. We may still be able to help.

Request a Quote